DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-24099

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Late (14:00–22:00) · 181 of 193 min running
75%

Availability

94.0%

Performance

79.5%

Quality

100.0%

Current job
WO-24114
Bracket, actuator · AD-3310-A

Pieces

29 / 40

Cycle time

4m 56s

This piece

4m 55s elapsed

Operator

Arden Adams

Tool

T22 · Ø20 shell mill

Tool life left

91%

Finishes

07 Oct 18:05

Losses
Downtime by reason
11.6 minutes lost this shift, biggest first.

Setup / first-off

4.6 min

Tool change

2.6 min

No material

1.7 min

Waiting QA

1.1 min

No operator

0.7 min

Breakdown

0.7 min

Quality
Pieces this shift
Ideal 228 s versus actual 287 s per piece.

Good

37

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24114

High

Helvetica Medtech · AD-3310-A OP10 · Al 7075-T6 · setup 112 min

Late

29/40 · due 07 Oct 13:13

WO-24115

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 55 min

Queued

0/40 · due 09 Oct 08:13

WO-24116

Sandvik Tooling · ST-3390-A OP30 · H13 tool steel · setup 96 min

Queued

0/24 · due 10 Oct 03:13

Readings
Live telemetry
Polled every 5 seconds · spindle 18,506 h, service in 343 h

Spindle load

74 %

Spindle speed

8,794 rpm

Feed rate

1,633 mm/min

Spindle temp

50.4 °C

Coolant temp

27 °C

Coolant pressure

17.6 bar

Vibration

2.08 mm/s

Axis load B

30 %

Axis positions

X

-19.8

Y

-138.2

Z

-168.1

B

-53.1

C

15.9

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 10-07 16:03

high

B axis drive temperature high

Alarm 1105 · 10-07 15:12

medium

Tool life expired on T7, change required

Alarm 2019 · 10-07 14:51

low

B axis drive temperature high

Alarm 1105 · 10-06 21:21

medium

Tool life expired on T7, change required

Alarm 2019 · 10-06 15:16

high

Coolant level low in the tank

Alarm 7014 · 10-06 01:41

high

Coolant level low in the tank

Alarm 7014 · 10-06 00:54

high

Coolant level low in the tank

Alarm 7014 · 10-05 20:59

high